UV Bulbs and Parts
UV water disinfection systems are trusted to provide clean, healthy water, but they can't do their job if they aren't maintained properly. You need to change the germicidal UV lamp once a year, and make sure that all of the other parts are working correctly. US Water Systems offers a number of disinfection system parts, including UV sleeves, lamps, and ballasts, for the most popular ultraviolet water disinfection systems. We carry parts for Hydro-Safe, Polaris, Sterilight, Trojan, and other brands " and, of course, you'll get great deals on parts for US Water UV systems too! Not only do we have reliable products at reasonable prices, we also offer experienced tech support from Certified Water Specialists. Call 1-800-608-8792 and we'll be glad to discuss your water problems or system issues.
-
Trojan UVMAX Lamp And Sleeve Combo Kit Pro15/F/F4/ Plus Systems | 602810-104
Trojan Lamp (1): 602807 Trojan Quartz Sleeve (1): 602734 Trojan O-Rings (2): 2045 Trojan Part #602810-104-
$300.00 - $180.00
- Unit price
- per
-
-
Sterilight UV System Replacement Lamp S330RL
Sterilight S330RL Replacement Lamp Fits the following Sterilight (R-CAN) Models S2Q-PA S2Q-PA/2 SSM-17 SSM-17/2 S2Q S2Q/2 S2Q-GOLD S2Q-GOLD/2 SC4 SC4/2 Description 13.5" length 4-PIN staggered Replacement Interval 1 year/9000 hours-
$125.00 - $75.00
- Unit price
- per
-
-
Polaris UV Ballast 1-2 GPM 110 Volt
Polaris 110 Volt Ballast for 1 and 2 GPM Polaris UV Genuine Factory Replacement Fits Models UV-1C-110V and UV-2C-110V Replace as needed-
$73.25 - $43.95
- Unit price
- per
-
-
Trojan UVMAX Lamp for F, F Plus, F4, F4 Plus, Pro 15 | 602807
High Output UV replacement lamp for the Trojan UVMax-F, F Plus, F4, F4 Plus. Pro15 Model Systems Includes 2 O-Rings Includes Installation Instructions Genuine Trojan Replacement Part Trojan Part #602807 Lamp Replacement Diagram-
$238.67 - $143.20
- Unit price
- per
-
-
Trojan UVMAX Lamp for Pro20, H, H Plus | 602855
Trojan UVMAX Lamp for Pro20, H, H Plus Amalgam Lamp Includes 2 O-Rings Includes Installation Instructions Genuine Trojan Replacement Part Trojan Part #602855-
$365.00 - $219.00
- Unit price
- per
-
-
Hydro-Safe 8.0 GPM UV System Replacement Quartz Sleeve | HSQS-32
8.0 GPM Hydrosafe Replacement Quartz Sleeve HSQS-32 8.0 GPM 20x22.2x845 mm-
$98.34 - $59.00
- Unit price
- per
-
-
Instant Start Electronic Ballast 120V – GD40
Compatible with: Hallett 13 Hallett 30 Hallett 500 Series Hallett 750 Series Formerly Part # GA29/X100010-
$875.00 - $525.00
- Unit price
- per
-
-
Polaris Ultraviolet System Replacement Lamp 6 GPM
Genuine Factory Replacement Bulb for Polaris Scientific 6 GPM Ultraviolet Disinfection System Polaris Scientific Part Number GL24SE4P Fits Polaris UV-6C Ultraviolet System 4-Pin Connection-
$69.92 - $41.95
- Unit price
- per
-
-
UV Max O-Ring OR40-50
O-ring for the three piece, high flow plastic filter housings.-
$13.34 - $8.00
- Unit price
- per
-
-
Circuit Board PCB Fan – R400019B
Compatible with: Hallett 15xs Upstream NC10-75 Upstream NC10-50 Upstream NC15-75 Upstream NC15-50 Upstream NC30-75-
$50.00 - $30.00
- Unit price
- per
-
-
Polaris 2 GPM Replacement UV Lamp - 4 Pin
Polaris 1 GPM Replacement UV Lamp for Polaris Model UV-2C-14 or UV-2C-38 Genuine Factory Replacement Replace each year 4-Pin Connection-
$63.25 - $37.95
- Unit price
- per
-
-
US Water Pulsar Replacement Ultraviolet Lamp 15 GPM - High Output
US Water 15 GPM Replacement High Output Ultraviolet Lamp Genuine Factory Replacement Bulb Fits Model 406-PUV-HO-200-14 Pulsar Ultraviolet Light Commercial High Output Series Alternate Part Numbers: RL420-HO-
$256.91 - $154.14
- Unit price
- per
-
-
Blower – Reactor Cooling Kit with Filter – R400008
Compatible with: Hallett 15xs Upstream NC10-75 Upstream NC10-50 Upstream NC15-75 Upstream NC15-50 Upstream NC30-75-
$91.67 - $55.00
- Unit price
- per
-
-
Sterilight O-Ring OR-212
Typically 2 are required on all Sterilight Systems-
$10.00 - $6.00
- Unit price
- per
-
-
Trojan UVMAX Lamp for Pro10, G, G Plus | 602854
Trojan UVMAX Lamp for Pro10, G, G Plus Amalgam Lamp Includes 2 O-Rings Includes Installation Instructions Genuine Trojan Replacement Part Trojan Part #602854-
$381.34 - $228.80
- Unit price
- per
-
-
Hydro-Safe 1.0 GPM UV System Replacement Quartz Sleeve | HSQS-11
1.0 GPM Hydrosafe Replacement Quartz Sleeve HSQS-11 1.0 GPM 20x22.2x330 mm-
$88.25 - $52.95
- Unit price
- per
-
-
Sterilight Quartz Sleeve QS-330
Fits the following Sterilight (R-CAN) Models: S2Q-PA S2Q-PA/2 SSM-17 SSM-17/2 S2Q S2Q/2 S2Q-GOLD S2Q-GOLD/2 SC4 SC4/2-
$81.67 - $49.00
- Unit price
- per
-
-
-
Circuit Board / Ballast Combination Beta Board – H400001
Compatible with:Hallett 15xs-
$1,291.67 - $775.00
- Unit price
- per
-
-
Wiper Motor Kit 24V – R400005
Compatible with: Hallett 15xs Hallett 500 Series Hallett 750 Series Hallett 1000 Series Upstream NC10-75 Upstream NC10-50 Upstream NC15-75 Upstream NC15-50 Upstream NC30-75-
$116.67 - $70.00
- Unit price
- per
-
UV radiation can be used for multiple purposes in water treatment, but it is primarily employed as a tool to disinfect water, inactivating pathogens without chemicals. For other applications, UV can be used for the removal of organic and inorganic chemicals, including chlorine, chloramines, ozone and total organic carbon (TOC). When combined with oxidants such as ozone or hydrogen peroxide, or semiconductors such as titanium dioxide, UV can be used for the oxidation of refractory chemicals such as chlorinated solvents, taste and odor compounds, and other emerging contaminants.
UV System Parts
A UV water disinfection system is made up of several important parts:
- Germicidal UV lamp
- Ballast or controller unit
- Quartz sleeve
- Reaction chamber
Each of these parts must be in good working order to allow the system to work as it should. Water flows into the reaction chamber, which is sealed using O-rings. Inside this chamber is the UV lamp, which sits inside a quartz UV sleeve. The sleeve is a long, clear tube that protects the lamp while still allowing the correct UV rays to pass through and do their job. The ballast or controller powers the unit and controls the output of the germicidal UV lamp.
he UV lamp should be changed once a year to ensure that it's operating at peak efficiency. Always replace an old lamp with a new one designed to fit your system and provide the required dose of UV radiation to disinfect your water. When you replace the lamp, check the quartz sleeve; UV sleeves can become fouled with various contaminants over time. You may need to clean the sleeve or replace it if it's damaged or cannot be completely cleaned. It's a good idea to check your UV ballast at the same time to make sure that it's providing the power and control that you need.

The Benefits of UV Disinfection
UV disinfection has been successfully applied worldwide for decades, and has numerous advantages over chemical disinfection methods:
- Effective for all types of microorganisms, including bacteria, viruses, fungi, and protozoa, such as Cryptosporidium and Giardia
- Chemical-free technology, eliminating the need to transport, store, handle or remove potentially dangerous chemicals
- Non-corrosive and no hazards associated with accidental overdosing
- Low capital and operating cost
- Easy to operate and maintain
- No possibly dangerous disinfection by-products (DBPs) formed
- Compact and easy to retrofit
- Efficiency is independent of water pH
- No impact to the aesthetic quality of the water (taste, odor, color)
- Safe and environmentally-friendly
If you have questions about ultraviolet disinfection or need technical help with your system, please call our Certified Water Specialists at 1-800-608-8792.