Select the Right Stenner Pump

Select The Right Stenner Pump

View the Stenner peristaltic pump line at a glance with the essential attributes summarized in the charts below. Click the pump name to view all the data or select a link to view specific information.

Classic Pump Line
Up to 100 psi (6.9 bar) 

Pump Output Range Type Control
US Standard Metric

Classic Single Head Adjustable

0.2 - 85.0 gpd 0.8 - 321.8 lpd Electro-mechanical
  • External dial ring
  • 20:1 turndown
  • 2.5% increments

Classic Single Head Fixed

3.0 - 85.0 gpd 11.4 - 321.8 lpd Electro-mechanical No adjustment

Classic Double Head Adjustable

0.3 - 170.0 gpd 1.1 - 643.5 lpd Electro-mechanical
  • External dial ring
  • 20:1 turndown
  • 2.5% increments

Classic Double Head Fixed

6.0 - 170.0 gpd 22.7 - 643.6 lpd Electro-mechanical No adjustment

SVP

0.3 - 85 gpd 1.1 - 321.8 lpd Variable Speed
  • Digital keypad
  • Manual control or automatic via 4-20mA signal
  • 20:1 turndown
  • 1% increments

M128

8.4 oz/min 249.7 ml/min 1:128 Medicator
  • Actuated by a dry contact water meter
  • Adjustable potentiometer for meter pulse rate
  • Signal splitter

Econ Pump Line
Up to 80 psi (5.5 bar) 

Pump Output Range Type Control
US Standard Metric

Econ FP

4.5 - 30.0 gpd 17.0 - 113.8 lpd Flow Activated Accepts a singnal from:
  • Dry contact water meter
  • Dry contact flow switch
  • 12-24 VAC/VDC water softener or flow control equipment

Econ T

3.0 - 115.2 oz/hr 396.0 - 3416.4 ml/hr Programmable Timer
  • Digital keypad
  • 24 separate on & off events within a 7 day period
  • Hour & minute increments