SIGN UP FOR OUR NEWSLETTER
Receive our latest updates about our products & promotions.
Save Up to 50% with Factory Direct Pricing
Plus an additional 20% - 25% Off Select Systems!





Order by 12 PM EST and this system will be on its way the very next day.
Free standard shipping on most products over $199.
Free shipping on most orders over $199 in the continental USA. $299 minimum for extended delivery states: AK, AL, AZ, CA, HI, ID, MD, ME, MN, MS, MT, NH, NV, OR, UT, VA, VT, WA, WV. Freight orders excluded. Speak to a water expert for more details.
Our Master Water Specialists and Certified Water Specialists review your water analysis and address your specific water problems. WE then design a system that we'll guarantee will solve your water problem(s) and back it with our One-Year Money Back Promise (Guarantee).
It all starts with a Laboratory Test of your water. Then, our Master Water Specialists and Certified Water Specialists will review the results of your water analysis and scientifically discuss the best way to treat your water, provide on estimate of how to do that, and then we provide you a One-Year Guarantee of Satisfaction. It's our Promise to You that our system will do what we say or we will give you your money back*
Effluent UV disinfection that wipes its own quartz sleeves, measures the UV reaching your water, and alarms before a dark bulb or fouled sleeve shows up in your fecal counts.Self-cleaning wastewater UV that alarms before a dark bulb or dirty sleeve fails your permit.
Hallett W Series wastewater UV systems treat up to 40 GPM per unit on the 500W and 750W, and up to 75 GPM per unit on the 1000W. Configure your build and see the price now, or run your flow, UVT and permit past a Certified Water Specialist first.
Live pricing. Data sheet for every model. Certified Water Specialists at 800-608-8792.
Start with your peak flow. Then check your effluent's UV transmittance (UVT, the share of UV light that passes through the water) and the dose your permit calls for against the table. More flow means lower dose. Lower UVT or a higher required dose means less flow per unit. EPA's guidance is plain: "Any UV disinfection system should be pilot tested prior to full-scale operation."
| 500W | 750W | 1000W | |
|---|---|---|---|
| Flow, single unit (data sheet) | Up to 40 GPM | Up to 40 GPM | Up to 75 GPM |
| UVT range | 50-95% | 50-95% | 35-80% |
| UV dose | Min. 30 mJ/cm² | Min. 30 mJ/cm² | 16-60 mJ/cm² |
| Lamps and typical life | Dual LPHO, 9,000 h | Dual LPHO, 9,000 h | Dual amalgam, 12,000 h |
| Lamp starts per 24 h (data sheet) | Max 2 | Max 2 | Max 6-12 |
| UV sensors | Dual | Dual | Quad |
| Ports | 1" MNPT stainless | 1" MNPT stainless | 2" MNPT stainless |
| Power and voltage | 196 W, 120 V | 222 W, 120 V | 403 W, 120/230 V |
| H x W x D | 36.5 x 9.6 x 8.6 in. | 40.4 x 9.6 x 8.6 in. | 55.8 x 11.5 x 8.6 in. |
| Performance validation | None third party | None third party | US EPA UVDGM |
Flow is each data sheet's single-unit rating. At low UVT or a high required dose, one unit treats less, so size those jobs with a specialist.
Who sets the flow: you do. The operator enters the target flow on the controller, and the unit calculates dose against that flow and alarms when dose falls short. The setting does not physically cap flow; if actual flow runs above it the unit can underdose, so fit the optional flow restrictor where peak demand could exceed the setting.
Have these ready when you call 800-608-8792: peak flow, a lab UVT result, the dose or limits in your permit, and your line voltage.
Crossfire is UV Pure's dual-lamp, elliptical-reflector design. Standard on every W model: automatic wiper with position switch, purge valve, forced-air cooling, color touchscreen, remote start/stop, onboard diagnostics and two dry contacts.
Two lamps, light from every side. Water runs through a quartz sleeve while two lamps sit in air beside it. An elliptical reflector sends UV back into the water from 360 degrees. The short light path helps in low-UVT water, and because the lamps sit out of the water, you change one without draining the system.
A wiper that proves it moved. An automatic wiper cleans the quartz sleeve for five minutes every four hours. A position switch confirms it is moving, and the controller posts a "Wiper Not Turning" warning if it stalls.
Sensors that measure, not assume. Dual (500W, 750W) or quad (1000W) UV sensors, calibrated to NIST standards, read UV intensity, dose (the UV energy delivered, in mJ/cm²) and UVT. The controller checks the delivered dose against the target flow you entered, so fouling or an aging lamp shows up as a lower reading, not a guess.
Alarms before a lab result. When dose falls short, the touchscreen alarms and a dry contact opens for your panel or SCADA. Add the optional valve and the unit shuts the line too. Message History keeps the last 100 events for your records.
When Washington State's Department of Health checked UV units at onsite sewage systems, it found "25% could not provide disinfection because the UV bulb was not glowing." The W Series is built so a dark lamp or a fouled sleeve shows up as an alarm, not as a failed sample.
UV sensors read actual output, and the controller alarms when dose falls short. Two dry contacts send warning and alarm to your panel, so nobody has to stand watch.
The wiper cleans on its own schedule and flags it if it stalls. Lamps come out without draining the unit, so a change is a short job.
A published price, a data-sheet flow for each model and a part number in the cart. A 40 GPM job shouldn't need a round of quotes.
Each model has its own data sheet, and the 1000W is validated to the US EPA UVDGM protocol. Every spec on this page traces to those sheets and the O&M manual.
Small municipal wastewater treatment plant (WWTP) and package-plant effluent: alarm contacts for sites without a full-time operator, and the 1000W where the permit calls for UVDGM validation.
Industrial discharge: 4-20 mA and Modbus report dose and UVT into your SCADA.
Aquaculture and fish hatcheries: disinfection with nothing added to the water.
Lagoon effluent: check solids against the limits below and pre-filter where needed.
Land application and irrigation discharge: size to the peak pump rate, not the daily average.
Operating limits (data sheets and O&M manual): pressurized line at 5-100 psig; hardness up to 855 mg/L; iron up to 3 mg/L; total suspended solids (TSS) up to 20 mg/L per the O&M manual, so pre-filter where TSS runs higher; water 34-104°F (500W, 750W) or 34-95°F (1000W); relative humidity up to 70%. Water outside these limits is not serviceable under warranty.
Every spec on this page comes from these documents. Send them to your engineer or regulator before you order.
Technical documentation
500W technical data sheet (PDF): flow, UVT, dose, dimensions, certifications and warranty.
750W technical data sheet (PDF): the same data for the 750W, including its taller body and 222 W draw.
1000W technical data sheet (PDF): adds the US EPA UVDGM validation, 230 V and the multi-unit note.
GH44P operation and maintenance manual (PDF): installation, controller setup including target flow, alarms, wiper and lamp service.
Each model carries only what its own data sheet lists. For a permit submittal, send the reviewer that model's data sheet and the O&M manual.
The 1000W data sheet lists performance validation to the US EPA Ultraviolet Disinfection Guidance Manual (UVDGM) protocol, the EPA framework for testing the dose a UV reactor actually delivers. This applies to the 1000W only.
The 1000W data sheet lists the IECEE CB Scheme (international electrical safety testing) and the CE Mark alongside its UVDGM validation.
Each W data sheet lists UL 979, the UL standard for water treatment appliances.
Wetted parts meet NSF/ANSI/CAN 61 and NSF/ANSI 372 for water up to 73°F (23°C). This covers material safety and lead content, not disinfection performance.
The 500W and 750W carry no third-party performance validation. If your permit requires one, choose the 1000W or call a specialist before you order.
Small onsite gravity units top out around 10 GPM. Engineered municipal systems are sold by quote. The W Series covers the gap between them.
| Hallett W Series | Onsite gravity units | Engineered OEM systems | |
|---|---|---|---|
| Pricing | Published price | Dealer pricing | Quote only |
| Flow per unit | Up to 40 GPM (500W, 750W); up to 75 GPM (1000W) | Up to about 10 GPM | Often unpublished |
| Sleeve cleaning | Automatic wiper, every model | Mostly hand-cleaned | Automatic on many; extra cost on some |
| UV monitoring | Sensors measure intensity and UVT | Lamp-on indicator | Standard on most, optional on some |
| Alarm outputs | Two dry contacts; 4-20 mA and Modbus option | Lamp relay on some | Varies by system |
| Operating pressure | 5-100 psig | Gravity | 40 psi max on some standard models |
| Third-party validation | US EPA UVDGM (1000W only) | Onsite test protocols on some | Reuse validations on some |
Where others lead: some engineered systems offer reuse validations, flow-paced dosing and single units above 100 GPM. If your job needs those, we will tell you.
Only the 1000W is validated, to the US EPA UVDGM protocol; the 500W and 750W carry no third-party performance validation. Acceptance depends on your permit, so send your regulator the data sheet for the model you plan to buy, and follow EPA's advice to pilot test before full-scale operation.
The controller alarms and opens a dry contact you can wire to your panel or SCADA, and the RUN contact also opens on power loss or a cut wire. On the 500W and 750W, the optional 1-inch solenoid valve is normally closed, so it shuts the line on alarm and on power failure. On the 1000W, the optional 2-inch actuated ball valve shuts the line on alarm; ask a specialist how to handle power loss on your site.
It needs effluent within these limits: TSS up to 20 mg/L per the O&M manual, hardness up to 855 mg/L, iron up to 3 mg/L, and UVT of 50-95% on the 500W and 750W or 35-80% on the 1000W. EPA notes low-pressure UV is "not as effective" above 30 mg/L TSS, so filter upstream if your solids run high. Send a specialist your lab UVT and TSS results and get a straight read on fit.
Up to 40 GPM with UVT of 50% or better and no validation requirement points to the 500W or 750W. Above 40 GPM, lower UVT, frequent lamp starts or a UVDGM requirement points to the 1000W. The 500W and 750W share the same data-sheet flow, UVT and dose; the 750W has a larger UV chamber (222 W vs 196 W draw), and a specialist can tell you if that difference matters for your effluent.
Your operator sets the target flow on the controller; this page lists one number per model, the data sheet's single-unit flow. The unit calculates dose against the flow you enter and alarms when dose falls short. The setting does not physically cap flow; if actual flow runs above it the unit can underdose, so fit the optional flow restrictor where peak demand could exceed the setting.
Frequent cycling points to the 1000W: the data sheets list a maximum of 2 lamp starts per 24 hours on the 500W and 750W, and 6-12 on the 1000W. If you are unsure how often your lamps will restart, call a specialist. With the lamps left on, the built-in purge valve flushes the chamber during no-flow periods so it doesn't overheat.
Plan a lamp change at typical lamp life: 9,000 hours on the 500W and 750W (about a year of continuous running) or 12,000 hours on the 1000W. The wiper cleans the sleeves on its own, and lamps change without draining the unit. The data-sheet limited warranty covers structural, hardware and mechanical parts 5 years, electrical and quartz sleeves 3 years, lamps 12 months (16 on the 1000W) and sensor probes 1 year. Use genuine Hallett UV Pure parts: non-genuine parts void the warranty.
Yes, a qualified contractor can, following the O&M manual. The unit needs a pressurized line at 5-100 psig, a vertical, vibration-free wall mount, a drain for the purge line and metal outlet piping (the manual says do not use PVC). 120 V is standard; for 230 V, which only the 1000W data sheet lists, call for availability. A specialist can walk your installer through it by phone.
Yes. The 1000W data sheet notes a 100 GPM maximum flow for a single unit and multi-unit systems up to 1 MGD by quote. Use the Custom & multi-unit quote link or call a specialist with your peak flow and UVT, so the quote reflects your actual effluent.
Hallett units are built by UV Pure Technologies, a Canadian UV manufacturer. Don't take our word for the rest: read the data sheets and O&M manual above, the same documents your engineer will review. Then call a Certified Water Specialist at 800-608-8792 with your flow, UVT and permit limits, and get a straight answer on fit.
Configure your W Series wastewater UV system above and see the live price and part number for your exact build. Low UVT, a high required dose, more than one unit or a permit question? Talk to a Certified Water Specialist at 800-608-8792 before you order.
Live pricing on every build. Data sheets and O&M manual linked above.
Receive our latest updates about our products & promotions.
Thanks for subscribing!
This email has been registered!