Hallett W Series Wastewater UV

List Price: Factory Direct Price: SALE PRICE:
$2,983.34
$2,983.34
$2,983.34 FACTORY DIRECT SAVINGS

Blowout Sale Ends:

Optional Upgrades:

+$229.17
+$116.68
+$2,000.00
+$408.34
SKU: 406-WW-500W-120-S
Self-cleaning wastewater UV disinfection for effluent, rated up to 40 GPM per unit on the 500W and 750W and up to 75 GPM on the 1000W. UV sensors track the dose, and the unit alarms before a dark lamp or fouled sleeve affects your permit. US EPA UVDGM validated on the 1000W.
Subtotal: $2,983.34

Free Shipping

Free standard shipping on most products over $199.

One Year Satisfaction Guarantee

Learn More.
Hallett W Series Wastewater UV - US Water Systems

Hallett W Series Wastewater UV

$4,972.23 $2,983.34

Hallett W Series Wastewater UV

$4,972.23 $2,983.34
Model: 500W
Communication: Standard
W Series, Wastewater

Hallett W Series: Wastewater UV Disinfection Systems

Effluent UV disinfection that wipes its own quartz sleeves, measures the UV reaching your water, and alarms before a dark bulb or fouled sleeve shows up in your fecal counts.Self-cleaning wastewater UV that alarms before a dark bulb or dirty sleeve fails your permit.

Hallett W Series wastewater UV systems treat up to 40 GPM per unit on the 500W and 750W, and up to 75 GPM per unit on the 1000W. Configure your build and see the price now, or run your flow, UVT and permit past a Certified Water Specialist first.

  • US EPA UVDGM validated (1000W)
  • Self-cleaning sleeve wiper, every model
  • Up to 75 GPM per unit (1000W)
  • Wetted parts meet NSF/ANSI/CAN 61 & 372
  • Low-dose alarm and dry contacts, every model

Live pricing. Data sheet for every model. Certified Water Specialists at 800-608-8792.

Hallett 1000W wastewater UV disinfection system, front view with lit touchscreen
Hallett logo

Which W model fits your effluent flow and UVT

Start with your peak flow. Then check your effluent's UV transmittance (UVT, the share of UV light that passes through the water) and the dose your permit calls for against the table. More flow means lower dose. Lower UVT or a higher required dose means less flow per unit. EPA's guidance is plain: "Any UV disinfection system should be pilot tested prior to full-scale operation."

  500W 750W 1000W
Flow, single unit (data sheet) Up to 40 GPM Up to 40 GPM Up to 75 GPM
UVT range 50-95% 50-95% 35-80%
UV dose Min. 30 mJ/cm² Min. 30 mJ/cm² 16-60 mJ/cm²
Lamps and typical life Dual LPHO, 9,000 h Dual LPHO, 9,000 h Dual amalgam, 12,000 h
Lamp starts per 24 h (data sheet) Max 2 Max 2 Max 6-12
UV sensors Dual Dual Quad
Ports 1" MNPT stainless 1" MNPT stainless 2" MNPT stainless
Power and voltage 196 W, 120 V 222 W, 120 V 403 W, 120/230 V
H x W x D 36.5 x 9.6 x 8.6 in. 40.4 x 9.6 x 8.6 in. 55.8 x 11.5 x 8.6 in.
Performance validation None third party None third party US EPA UVDGM

Flow is each data sheet's single-unit rating. At low UVT or a high required dose, one unit treats less, so size those jobs with a specialist.

Who sets the flow: you do. The operator enters the target flow on the controller, and the unit calculates dose against that flow and alarms when dose falls short. The setting does not physically cap flow; if actual flow runs above it the unit can underdose, so fit the optional flow restrictor where peak demand could exceed the setting.

  • Pick the 500W or 750W for up to 40 GPM, UVT of 50% or better, and no validation requirement.
  • Pick the 1000W when your regulator wants US EPA UVDGM validation, when flow runs past 40 GPM or UVT drops below 50%, or when the lamps will cycle often.

Have these ready when you call 800-608-8792: peak flow, a lab UVT result, the dose or limits in your permit, and your line voltage.

How self-cleaning Crossfire UV keeps the dose on target

Crossfire is UV Pure's dual-lamp, elliptical-reflector design. Standard on every W model: automatic wiper with position switch, purge valve, forced-air cooling, color touchscreen, remote start/stop, onboard diagnostics and two dry contacts.

Hallett 750W wastewater UV disinfection system

Two lamps, light from every side. Water runs through a quartz sleeve while two lamps sit in air beside it. An elliptical reflector sends UV back into the water from 360 degrees. The short light path helps in low-UVT water, and because the lamps sit out of the water, you change one without draining the system.

A wiper that proves it moved. An automatic wiper cleans the quartz sleeve for five minutes every four hours. A position switch confirms it is moving, and the controller posts a "Wiper Not Turning" warning if it stalls.

Sensors that measure, not assume. Dual (500W, 750W) or quad (1000W) UV sensors, calibrated to NIST standards, read UV intensity, dose (the UV energy delivered, in mJ/cm²) and UVT. The controller checks the delivered dose against the target flow you entered, so fouling or an aging lamp shows up as a lower reading, not a guess.

Alarms before a lab result. When dose falls short, the touchscreen alarms and a dry contact opens for your panel or SCADA. Add the optional valve and the unit shuts the line too. Message History keeps the last 100 events for your records.

Why wastewater operators choose the W Series

When Washington State's Department of Health checked UV units at onsite sewage systems, it found "25% could not provide disinfection because the UV bulb was not glowing." The W Series is built so a dark lamp or a fouled sleeve shows up as an alarm, not as a failed sample.

Hear about a dark bulb from the alarm, not the lab.

UV sensors read actual output, and the controller alarms when dose falls short. Two dry contacts send warning and alarm to your panel, so nobody has to stand watch.

Stop pulling sleeves to scrub them.

The wiper cleans on its own schedule and flags it if it stalls. Lamps come out without draining the unit, so a change is a short job.

Price it yourself. No quote cycle.

A published price, a data-sheet flow for each model and a part number in the cart. A 40 GPM job shouldn't need a round of quotes.

Paperwork your engineer and regulator can check.

Each model has its own data sheet, and the 1000W is validated to the US EPA UVDGM protocol. Every spec on this page traces to those sheets and the O&M manual.

Wastewater applications for the W Series

Small municipal wastewater treatment plant (WWTP) and package-plant effluent: alarm contacts for sites without a full-time operator, and the 1000W where the permit calls for UVDGM validation.

Industrial discharge: 4-20 mA and Modbus report dose and UVT into your SCADA.

Aquaculture and fish hatcheries: disinfection with nothing added to the water.

Lagoon effluent: check solids against the limits below and pre-filter where needed.

Land application and irrigation discharge: size to the peak pump rate, not the daily average.

Operating limits (data sheets and O&M manual): pressurized line at 5-100 psig; hardness up to 855 mg/L; iron up to 3 mg/L; total suspended solids (TSS) up to 20 mg/L per the O&M manual, so pre-filter where TSS runs higher; water 34-104°F (500W, 750W) or 34-95°F (1000W); relative humidity up to 70%. Water outside these limits is not serviceable under warranty.

Hallett W Series spec sheets and O&M manual

Every spec on this page comes from these documents. Send them to your engineer or regulator before you order.

Technical documentation

500W technical data sheet (PDF): flow, UVT, dose, dimensions, certifications and warranty.

750W technical data sheet (PDF): the same data for the 750W, including its taller body and 222 W draw.

1000W technical data sheet (PDF): adds the US EPA UVDGM validation, 230 V and the multi-unit note.

GH44P operation and maintenance manual (PDF): installation, controller setup including target flow, alarms, wiper and lamp service.

Hallett 1000W wastewater UV system, angled view

Certifications and US EPA UVDGM validation (1000W)

Each model carries only what its own data sheet lists. For a permit submittal, send the reviewer that model's data sheet and the O&M manual.

The 1000W data sheet lists performance validation to the US EPA Ultraviolet Disinfection Guidance Manual (UVDGM) protocol, the EPA framework for testing the dose a UV reactor actually delivers. This applies to the 1000W only.

How the W Series compares to other effluent UV systems

Small onsite gravity units top out around 10 GPM. Engineered municipal systems are sold by quote. The W Series covers the gap between them.

  Hallett W Series Onsite gravity units Engineered OEM systems
Pricing Published price Dealer pricing Quote only
Flow per unit Up to 40 GPM (500W, 750W); up to 75 GPM (1000W) Up to about 10 GPM Often unpublished
Sleeve cleaning Automatic wiper, every model Mostly hand-cleaned Automatic on many; extra cost on some
UV monitoring Sensors measure intensity and UVT Lamp-on indicator Standard on most, optional on some
Alarm outputs Two dry contacts; 4-20 mA and Modbus option Lamp relay on some Varies by system
Operating pressure 5-100 psig Gravity 40 psi max on some standard models
Third-party validation US EPA UVDGM (1000W only) Onsite test protocols on some Reuse validations on some

Where others lead: some engineered systems offer reuse validations, flow-paced dosing and single units above 100 GPM. If your job needs those, we will tell you.

Hallett W Series wastewater UV FAQ

Which W model is EPA validated, and will my regulator accept it?

Only the 1000W is validated, to the US EPA UVDGM protocol; the 500W and 750W carry no third-party performance validation. Acceptance depends on your permit, so send your regulator the data sheet for the model you plan to buy, and follow EPA's advice to pilot test before full-scale operation.

What happens if the power drops or the dose falls short overnight?

The controller alarms and opens a dry contact you can wire to your panel or SCADA, and the RUN contact also opens on power loss or a cut wire. On the 500W and 750W, the optional 1-inch solenoid valve is normally closed, so it shuts the line on alarm and on power failure. On the 1000W, the optional 2-inch actuated ball valve shuts the line on alarm; ask a specialist how to handle power loss on your site.

What effluent quality does the W Series need?

It needs effluent within these limits: TSS up to 20 mg/L per the O&M manual, hardness up to 855 mg/L, iron up to 3 mg/L, and UVT of 50-95% on the 500W and 750W or 35-80% on the 1000W. EPA notes low-pressure UV is "not as effective" above 30 mg/L TSS, so filter upstream if your solids run high. Send a specialist your lab UVT and TSS results and get a straight read on fit.

500W, 750W or 1000W: which one fits my plant?

Up to 40 GPM with UVT of 50% or better and no validation requirement points to the 500W or 750W. Above 40 GPM, lower UVT, frequent lamp starts or a UVDGM requirement points to the 1000W. The 500W and 750W share the same data-sheet flow, UVT and dose; the 750W has a larger UV chamber (222 W vs 196 W draw), and a specialist can tell you if that difference matters for your effluent.

Why do listings show different flows, and who sets mine?

Your operator sets the target flow on the controller; this page lists one number per model, the data sheet's single-unit flow. The unit calculates dose against the flow you enter and alarms when dose falls short. The setting does not physically cap flow; if actual flow runs above it the unit can underdose, so fit the optional flow restrictor where peak demand could exceed the setting.

Our pumps cycle on and off all day. Is that a problem?

Frequent cycling points to the 1000W: the data sheets list a maximum of 2 lamp starts per 24 hours on the 500W and 750W, and 6-12 on the 1000W. If you are unsure how often your lamps will restart, call a specialist. With the lamps left on, the built-in purge valve flushes the chamber during no-flow periods so it doesn't overheat.

How much upkeep does it need, and what's under warranty?

Plan a lamp change at typical lamp life: 9,000 hours on the 500W and 750W (about a year of continuous running) or 12,000 hours on the 1000W. The wiper cleans the sleeves on its own, and lamps change without draining the unit. The data-sheet limited warranty covers structural, hardware and mechanical parts 5 years, electrical and quartz sleeves 3 years, lamps 12 months (16 on the 1000W) and sensor probes 1 year. Use genuine Hallett UV Pure parts: non-genuine parts void the warranty.

Can we install it ourselves, and what does the line need?

Yes, a qualified contractor can, following the O&M manual. The unit needs a pressurized line at 5-100 psig, a vertical, vibration-free wall mount, a drain for the purge line and metal outlet piping (the manual says do not use PVC). 120 V is standard; for 230 V, which only the 1000W data sheet lists, call for availability. A specialist can walk your installer through it by phone.

Our peak flow is over 75 GPM. Can we run more than one unit?

Yes. The 1000W data sheet notes a 100 GPM maximum flow for a single unit and multi-unit systems up to 1 MGD by quote. Use the Custom & multi-unit quote link or call a specialist with your peak flow and UVT, so the quote reflects your actual effluent.

I've never heard of Hallett, and there are no reviews. Why trust it?

Hallett units are built by UV Pure Technologies, a Canadian UV manufacturer. Don't take our word for the rest: read the data sheets and O&M manual above, the same documents your engineer will review. Then call a Certified Water Specialist at 800-608-8792 with your flow, UVT and permit limits, and get a straight answer on fit.

Size it, price it, order it

Configure your W Series wastewater UV system above and see the live price and part number for your exact build. Low UVT, a high required dose, more than one unit or a permit question? Talk to a Certified Water Specialist at 800-608-8792 before you order.

Live pricing on every build. Data sheets and O&M manual linked above.

Related Products

Recently Viewed Products

Cursor
Example product title
$4,972.23
From $2,983.34
Example product title
$4,972.23
From $2,983.34
Example product title
$4,972.23
From $2,983.34
Example product title
$4,972.23
From $2,983.34
Example product title
$4,972.23
From $2,983.34
Example product title
$4,972.23
From $2,983.34
Example product title
$4,972.23
From $2,983.34
Example product title
$4,972.23
From $2,983.34
Example product title
$4,972.23
From $2,983.34
Example product title
$4,972.23
From $2,983.34